Coal-based granular carbon for air purification
Activated Carbon for Air Purification: Coal-Based Granular Carbon for VOC and Odor Control
Coal-based granular activated carbon for fixed-bed air purification, offered across a reference range of iodine value, CTC adsorption, hardness and mesh size. It suits air streams carrying VOCs, solvent vapour or odour-causing components, where air passes through a granular layer at a defined contact time. Selection should follow actual gas components, concentration, temperature, humidity, airflow and allowable pressure drop, with batch values confirmed on the sample before quotation.
Compare iodine, CTC and hardness values, then confirm particle size and batch data on a sample before ordering.
- Iodine value
- 500 – 1100 mg/g
- Methylene blue adsorption
- ≥ 90 mg/g
- CTC adsorption
- 35 – 95 %
- Hardness
- ≥ 90 %
DESCRIPTION
Explore description details to support your evaluation.
This activated carbon for air purification is a coal-based granular material, supplied with a stated CTC adsorption range of 35–95% by the agreed test method. It is a starting point for air streams carrying VOCs, solvent vapour or odour-causing components, where the carbon is held in a fixed bed or adsorption box and the air passes through the granular layer.
How it works
Granular coal-based carbon has a pore structure that can hold a range of organic molecules. The bed gives the air a defined contact time, and adsorption depends on the target compound, its concentration, temperature, humidity and the amount of carbon in the vessel. CTC adsorption is a comparative indicator under one test method, not a guarantee of dynamic working capacity for every VOC or odour component.
Before selecting
Identify the target components and their concentration range so the duty is defined before sizing.
Note temperature, relative humidity and whether dust or oil mist needs pre-treatment ahead of the bed.
Confirm equipment form, allowable pressure drop, bed depth and the planned change-out or regeneration method.
Check particle size against the vessel and airflow: a finer cut may improve contact but can raise pressure drop and dust carry-over.
Limits and next step
Ordinary physical adsorption is not a universal solution: high humidity, high temperatures and mixtures of reactive components may need specific evaluation, and conditions involving flammable gases should be assessed by qualified personnel. To turn an enquiry into a usable recommendation, send the air stream composition and concentration, flow rate, temperature and humidity, current equipment and any target outlet limit, plus the required particle size and quantity.
SPECIFICATIONS
Explore specifications details to support your evaluation.
Specifications are reference series ranges, not a batch certificate. Confirm iodine value, CTC adsorption, hardness, moisture and mesh size on the sample before quotation.
| Iodine value | 500 – 1100 mg/g |
|---|---|
| Methylene blue adsorption | ≥ 90 mg/g |
| BET surface area | 650 – 1000 m²/g |
| CTC adsorption | 35 – 95 % |
| Ash content | 8 – 20 % |
| Moisture | ≤ 8 % |
| Hardness | ≥ 90 % |
| Bulk density | 0.5 – 0.65 g/cm³ |
| pH value | 7 – 11 |
| Particle size | 4 – 40 目 |
ADVANTAGES
Explore advantages details to support your evaluation.
These points help a buyer check whether the granular coal-based carbon and its documents fit an air purification duty.
Granular form for fixed beds
Coal-based granular carbon suits packed beds and adsorption boxes, so airflow resistance, bed depth and contact time can be reviewed with the particle size range.
Fits packed beds
OUR COMMITMENTS
Six Reasons Industrial Buyers Trust Sanniu Carbon
Our service commitments cover inquiry review, specification scope and batch confirmation, so you know exactly what is agreed before ordering.
Application and target review first
We review your air purification scenario, target components and required carbon form before discussing a selection direction, so the proposal matches the duty rather than a catalogue name.
Specification scope explained
We state the applicable range of the quoted specification sheet and remind you which values are series references. Batch figures are confirmed on the actual sample before quotation.
Batch values confirmed before quotation
Key items such as iodine value, CTC adsorption, hardness, moisture and particle size are confirmed against the batch offered, so the figures you compare come from the same basis.
Packaging and moisture protection agreed
At order confirmation we check packaging format and moisture-protection requirements against your storage and handling conditions, and record them in the confirmed order information.
Price, quantity and lead time verified by staff
Price, available quantity and delivery time are verified by our team and only confirmed in a written quotation or order; annual capacity is not presented as stock or lead time.
Post-delivery follow-up on use and documents
Through the agreed contact channel we follow up on questions about product use or documentation after delivery, without implying a fixed warranty or performance guarantee.
CREDENTIALS
Explore credentials details to support your evaluation.
ISO 9001:2015
Registrati0n No: 06524Q01338R0S
Certificate of Analysis
B-R2409C3836
Certificate of Analysis
Report No. A2260506150101001
Certificate of Analysis
No. 1621112086
Certificate of Analysis
NO.250100320443888
Certificate of Analysis
NO. 1524070087
PACKAGING
Explore packaging details to support your evaluation.
Granular carbon for gas-phase beds is packed to limit moisture pickup and dust during handling; the final packing is agreed with the order.
PROCESS
Explore process details to support your evaluation.
From first inquiry to post-delivery follow-up, each step keeps the selection basis and batch documents checkable before an order is placed.
Share the duty and operating data
Tell us the target gas or odor component, concentration range, temperature, humidity, airflow and the equipment or filter bed in use, so the discussion starts from real conditions.
Confirm material form and grade
We review the granular coal-based direction against the duty, then confirm which particle size, packing format and document set the application and site actually require.
Agree the specification and test method
Incoming values such as iodine value, CTC adsorption or hardness are compared only where the method, unit and sampling basis match, and the batch figure is confirmed before quotation.
Order confirmation and packing review
When the order is confirmed, packing specification, moisture protection and delivery requirements are checked together and recorded in the order information accepted by both sides.
Follow-up on use and documents
After delivery, questions about use or document scope are received and followed up through the agreed contact channel, with price, quantity and lead time confirmed by a person.
DIMENSIONS
Explore dimensions details to support your evaluation.
Granular coal-based carbon for fixed beds and adsorption boxes, selected around target gases, humidity, airflow and pressure drop rather than a single iodine number.
Product form
Granular activated carbon for gas-phase duty
Granular activated carbon sized for fixed beds and continuous gas or flue-gas streams, where pressure drop, hardness and dust behaviour matter alongside adsorption capacity.
Application
Air and gas purification
Odour control, solvent recovery and flue gas treatment, where the carbon has to hold up in the gas phase rather than in a water column.
Product form
Granular activated carbon
Granular media for fixed-bed adsorption and filtration. Compare particle size, pressure drop and handling needs.
FAQ
Explore faq details to support your evaluation.
What should I state when sending an inquiry about air-purification carbon?
Describe what the air stream contains and how the carbon will be used, so the grade can be matched to the duty rather than chosen from an iodine value alone. Useful details include the target compounds, concentration range, temperature, humidity, airflow, whether a fixed bed or adsorption box is planned, allowable pressure drop, and any pre-treatment for dust or oil mist.
How do the coal-based granular carbon specifications relate to air purification?
The frozen specification plan gives ranges for a coal-based granular grade, not a fixed promise for every batch. The iodine range covers 500 to 1,100 mg/g and BET surface area 650 to 1,000 m²/g; CTC adsorption is 35 to 95% by the agreed test method. Hardness is at least 90% and moisture at most 8%. These ranges describe material properties, and batch values are confirmed before quotation.
What do CTC adsorption and iodine value tell me about VOC and odor control?
CTC adsorption is a comparative gas-phase indicator obtained under a stated method. It does not equal the dynamic working capacity of every VOC, hydrogen sulfide or flue-gas component. Iodine value describes small-molecule adsorption under test conditions and is not a substitute for total surface area or removal rate. Selection should use the actual components, concentration, temperature and humidity of your stream, and the two values together with the contact time and bed design.
How do particle size, hardness and bulk density affect the adsorption bed?
Particle size is listed as 4 to 40 mesh, with the final mesh selected against your equipment and pressure-drop limits. A finer grade may improve contact but can raise resistance and dust carryover. Hardness of at least 90% and bulk density of 0.5 to 0.65 g/cm³ help estimate handling losses and bed weight, but test method and sample form should be comparable. Confirm these points against the existing filter, fan capacity and refill method.
Which test documents and batch details are confirmed before an order?
The quoted range is a series reference, so ask for the batch values and the test methods tied to them, together with the particle-size selection and moisture basis. Reports for a sample apply only to that sample unless a document says otherwise. Before ordering, agree the key acceptance items, the COA content and any third-party inspection, so the delivered lot can be checked against the same terms.
Can the specification be adjusted for a specific ventilation or odor-control system?
The ranges can be discussed against your stream and equipment, but changes must stay within the selected specification plan or be confirmed through the inquiry process. Provide the gas components, airflow, temperature, humidity, allowable pressure drop and refill constraints, and the suitable mesh, hardness and moisture basis can be reviewed. The final grade, price, available quantity and delivery date are confirmed by a person in writing, not by this page.