Sanniu Carbon
Air and gas purification
Odour control, solvent recovery and flue gas treatment, where the carbon has to hold up in the gas phase rather than in a water column.
Request a quoteDescription
Explore description details to support your evaluation.
Odour control, solvent recovery and flue gas treatment, where the carbon has to hold up in the gas phase rather than in a water column.
Gas-phase service is usually run with pelletised or coarse granular carbon, since pressure drop over deep beds is the limiting design value.
Selection parameters
Explore selection parameters details to support your evaluation.
These parameters are the starting point; final values follow the agreed specification plan.
Key parameter
Confirm this first, then discuss the rest.
Common CTC adsorption: ≥ 40 %
Operating conditions
Share the feed composition and the target outlet value.
Flow, concentration, contact time
Loading and change-out
Deep and shallow beds call for different particle sizes.
Bed depth and replacement cycle
Supply and packaging
Standard lead time 15 days; stock items 3-5 days.
25 kg bag / 500-1000 kg big bag
Related products
Explore related products details to support your evaluation.
Granular Activated Carbon for Air Purification: Selecting Iodine Value, Hardness and Mesh for Gas-Phase Service
Granular activated carbon for air purification is a coal-based gas-phase adsorbent for packed beds, adsorption boxes and filter vessels. It targets organic vapours, odours and solvent residues in exhaust streams where gas composition, humidity and flow are known. A defined bed depth makes contact time, pressure drop and replacement intervals plannable. CTC adsorption, iodine value and surface area help screen grades, but none predicts service life alone. Share the gas stream, airflow and allowable pressure drop to confirm batch values.
Activated Carbon for Odor Removal: How to Choose the Right Grade
Odor control with activated carbon starts with the gas stream, not the product name. This coal-based granular grade suits packed beds in enclosed rooms, exhaust ducts and adsorption boxes, where contact time, humidity and airflow affect working life. Iodine value and CTC adsorption help screen grades; hardness, ash and moisture indicate handling and bed stability. Share odor compounds, concentration, airflow and target outlet level to confirm the grade and next steps.
Activated Carbon for Air Purification: Coal-Based Granular Carbon for VOC and Odor Control
Coal-based granular activated carbon for fixed-bed air purification, offered across a reference range of iodine value, CTC adsorption, hardness and mesh size. It suits air streams carrying VOCs, solvent vapour or odour-causing components, where air passes through a granular layer at a defined contact time. Selection should follow actual gas components, concentration, temperature, humidity, airflow and allowable pressure drop, with batch values confirmed on the sample before quotation.
Activated Carbon for Solvent Recovery: Coal-Based Granular Grades for VOC Adsorption
Coal-based granular activated carbon for solvent recovery pairs a hard granule with a pore structure that captures organic vapours from air streams. Solvent-laden air passes through a fixed bed, and captured solvent can later be desorbed for reuse. It suits sites using chlorinated or non-chlorinated solvents where recovery beats disposal. Selection starts from the solvent, since concentration, temperature, humidity and airflow shape bed size and cycle life.
Granular Coal-Based Activated Carbon for Air Purification: Gas-Phase Media Selection Guide
Granular coal-based activated carbon is a gas-phase adsorbent for fixed beds, adsorber boxes and air purification systems. Air passes through a packed layer while the pore structure retains odorous and organic molecules, a duty pattern common in solvent vapour recovery, industrial exhaust odour control and spray booth extraction. Selection should rest on the target gas, concentration, temperature, humidity and airflow, not on a single headline figure.
Coal-Based Granular Activated Carbon for Waste Incineration Plant Flue Gas Treatment
Coal-based granular activated carbon for flue gas treatment in waste incineration plants. The granular form suits fixed-bed adsorbers, where bed depth, contact time and pressure drop can be planned around existing equipment. Iodine value, BET surface area and CTC adsorption serve as screening indicators under stated test methods; they compare batches but do not guarantee removal rates for a specific flue-gas stream. Batch values and available documents are confirmed before quotation.
Selection Recommended
Explore selection recommended details to support your evaluation.
Selection starts with the process, not the catalogue.
Share a representative sample
Explain how the sample reflects normal and peak operating conditions.
Agree test methods
Use consistent analytical methods when comparing trial results.
Fix the acceptance rule
Agree sampling and acceptance rules before shipment.
Related articles
Explore related articles details to support your evaluation.
Guangxi Direct Carbon Supply for Wastewater and Gases
Source manufacturing, traceability, impurities and practical treatment trials.
Sichuan Coal Carbon for Sulfur and NOx Treatment
Sanniu discusses grade fit, impurity control, custom forms and direct supply.
Hebei High-Flow Gas Treatment: Honeycomb Carbon and Delivery
Assess geometry, strength, moisture, applicable tests and dependable project supply.
Desulfurization Carbon for Guangxi: Strong, Regenerable Coal Grades
Review sulfur duty, mechanical strength, batch data and regional supply.
Pellet Gas Carbon for Guizhou: Quality and Supply
Match pellet carbon to gas composition, humid storage and recurring supply needs.
Honeycomb Gas Carbon for Sichuan: Specifications and Supplier Checks
Assess honeycomb grade, size, strength, pressure loss and batch evidence.
Faq
Explore faq details to support your evaluation.
Can air and gas purification be mixed with another carbon in one bed?
Yes, but when loading in layers keep the particle sizes close to avoid channelling, and record the test data for each layer.
What is the minimum order quantity?
One tonne for normal orders; samples of 1-5 kg can be shipped with freight paid by the customer.
What lead time should we expect?