Coal-based granular carbon for flue gas
Coal-Based Granular Activated Carbon for Waste Incineration Plant Flue Gas Treatment
Coal-based granular activated carbon for flue gas treatment in waste incineration plants. The granular form suits fixed-bed adsorbers, where bed depth, contact time and pressure drop can be planned around existing equipment. Iodine value, BET surface area and CTC adsorption serve as screening indicators under stated test methods; they compare batches but do not guarantee removal rates for a specific flue-gas stream. Batch values and available documents are confirmed before quotation.
For incineration flue gas: confirm gas components, temperature, humidity and flow before selecting a grade.
- Iodine value
- 500 – 1100 mg/g
- Methylene blue adsorption
- ≥ 90 mg/g
- CTC adsorption
- 35 – 95 %
- Hardness
- ≥ 90 %
DESCRIPTION
Explore description details to support your evaluation.
Coal-based granular activated carbon is a porous adsorbent made from coal and formed into granules for fixed-bed gas treatment. In waste incineration plants, flue gas carries a changing mix of organic vapours, odorous compounds and trace volatile species after the main acid-gas and particulate stages. The granular form suits column loading and a defined bed depth.
How the bed works
Gas passes through the carbon bed, where organic molecules are held on the internal pore surface. Adsorption depends on the target compound, its concentration, temperature, humidity and contact time, not on a single headline figure. Iodine value, surface area and CTC adsorption are comparison values for pore accessibility and vapour-phase behaviour, not guaranteed removal rates for a specific flue-gas stream. Hardness, bulk density, moisture and ash should be compared on the same basis.
Selection information
Before choosing a grade, establish the gas composition and its variation, operating temperature and humidity, flow rate and permitted pressure drop, pre-treatment for dust, acid gases and moisture, and the target outlet condition. Confirm single-pass or regenerative use and vessel dimensions so the particle size grade matches loading and flow. Because incineration flue gas is complex and often humid, on-site comparison under actual conditions is more informative than datasheets alone.
The specification table shows the series reference ranges for this product. Batch values are confirmed before quotation, and the mesh grade is agreed per order. For an inquiry, include the treatment target, gas flow and temperature, humidity, equipment type, particle size and quantity.
SPECIFICATIONS
Explore specifications details to support your evaluation.
Values below are series reference ranges for a granular coal-based product. Confirm the applicable grade, method and batch results before quotation.
| Iodine value | 500 – 1100 mg/g |
|---|---|
| Methylene blue adsorption | ≥ 90 mg/g |
| BET surface area | 650 – 1000 m²/g |
| CTC adsorption | 35 – 95 % |
| Ash content | 8 – 20 % |
| Moisture | ≤ 8 % |
| Hardness | ≥ 90 % |
| Bulk density | 0.5 – 0.65 g/cm³ |
| pH value | 7 – 11 |
| Particle size | 4 – 40 目 |
ADVANTAGES
Explore advantages details to support your evaluation.
For waste incineration flue gas, the useful questions are bed behaviour, gas-phase screening data and batch consistency, not a single headline number.
Granular form suited to fixed-bed adsorbers
A coal-based granular grade packs into a defined bed, so contact time, pressure drop and change-out intervals can be planned around the plant's existing adsorber and fan capacity.
Bed-based handling
OUR COMMITMENTS
Six Reasons Industrial Buyers Trust Sanniu Carbon
Application review before selection
Share the flue gas composition, temperature, humidity, flow rate and target limits first. We check them against the coal-based granular carbon's intended duty before discussing a grade.
Specifications and document scope confirmed
We state the applicable range of the cited iodine value, CTC adsorption, hardness and other indicators, and confirm batch values and available documents before the order.
Packing and moisture protection agreed
Bag type, net weight and moisture-control requirements are reviewed at order confirmation and recorded in the mutually confirmed order information.
Price, quantity and lead time verified by staff
Quotations, available quantities and delivery schedules are checked by our team and confirmed in writing; this page does not represent stock or a fixed lead time.
Post-delivery follow-up
Questions about handling, use or documents after delivery are received and followed up through the agreed contact channel.
CREDENTIALS
Explore credentials details to support your evaluation.
ISO 9001:2015
Registrati0n No: 06524Q01338R0S
Certificate of Analysis
B-R2409C3836
Certificate of Analysis
Report No. A2260506150101001
Certificate of Analysis
No. 1621112086
Certificate of Analysis
NO.250100320443888
Certificate of Analysis
NO. 1524070087
PACKAGING
Explore packaging details to support your evaluation.
PROCESS
Explore process details to support your evaluation.
From first inquiry to order confirmation, each step keeps the selection basis and batch documentation checkable before commitment.
Share the flue-gas duty and operating conditions
Tell us the target components, concentration range, temperature and humidity, airflow, pretreatment, equipment form and allowed pressure drop, so the gas-phase duty is understood before any grade is proposed.
Agree the selection direction and form
We review the application with you and discuss a coal-based granular direction, particle size and bed arrangement that fit the existing adsorber, fan and change-out practice.
Confirm specification scope and documents
The quoted specification and any referenced reports are tied to their stated scope; batch values and available documents are confirmed before the transaction, not inferred from a series range.
Check packing and moisture protection
At order confirmation, bag type, bulk-bag size, palletisation and moisture protection for the shipping route are reviewed together and recorded in the confirmed order information.
Confirm price, quantity and delivery in writing
Price, available quantity and lead time are verified by our team and only take effect through the written quotation or order both sides confirm; the published capacity figure is not a stock or delivery promise.
DIMENSIONS
Explore dimensions details to support your evaluation.
Granular coal-based activated carbon suits fixed-bed and adsorption-box flue gas duty. Size the bed around actual gas conditions, not a single indicator.
Material
Coal-based activated carbon for mercury removal
Coal-based activated carbon, usually impregnated with sulfur or a halogen, selected for the pore profile and surface chemistry that suit elemental and oxidised mercury species in gas streams.
Product form
Granular activated carbon for gas-phase duty
Granular activated carbon sized for fixed beds and continuous gas or flue-gas streams, where pressure drop, hardness and dust behaviour matter alongside adsorption capacity.
Application
Air and gas purification
Odour control, solvent recovery and flue gas treatment, where the carbon has to hold up in the gas phase rather than in a water column.
FAQ
Explore faq details to support your evaluation.
What information is needed to quote coal-based granular carbon for incineration flue gas?
Send the flue-gas composition and expected mercury or other target concentrations, temperature and humidity, flow rate, and the equipment type, including bed depth and allowable pressure drop. Also confirm the required particle size, moisture basis for acceptance, packaging, quantity and delivery location. We then confirm the applicable grade, batch specification and documents before pricing; price, availability and lead time are verified manually, not quoted from this page.
How should the iodine value and CTC adsorption figures be used for flue-gas duty?
Treat them as screening indicators, not as the working capacity of a specific gas. Iodine value (500–1100 mg/g range in this series) reflects small-molecule probe adsorption under a defined test. CTC adsorption (35–95% range) is a comparative gas-phase test, but it does not equal dynamic capacity for every VOC, mercury species or acid gas. Final selection should combine target gas data, contact time, humidity and a like-for-like test on the actual flue gas.
Which specifications matter for fixed-bed or injection operation?
For a fixed bed, particle size (4–40 mesh range), hardness (≥90% reference), bulk density (0.5–0.65 g/cm³ range) and allowable pressure drop all affect bed volume, retention time and carbon loss. For powder injection, particle size and dispersion matter more. Ash content (8–20% range) and moisture (≤8% reference) affect the effective dry mass and handling. Exact screening grade and batch values are agreed before quotation, not assumed from the series range.
Can this coal-based carbon be applied to mercury removal from incinerator flue gas?
Coal-based granular carbon is a recognized option for flue-gas adsorption, and the granular coal series in this page is discussed for waste incineration flue gas. However, mercury removal depends on the mercury speciation, flue-gas temperature, acid gases, moisture, dust and contact time, and may require an impregnated or tailored grade rather than standard carbon. Confirm the required grade and validate performance with representative gas conditions before committing to a specification.
What checks should be agreed before shipment for a flue-gas carbon order?
Agree the grade, key specification items, test methods and units, sampling and re-test method, moisture basis, particle size distribution, packaging and moisture protection, and the documents required for each batch. Keep a retained sample and comparable records so that later batch variation can be traced against the agreed basis. Batch-specific values and available reports are confirmed before the order, not taken from the series ranges shown on this page.
How can regeneration or replacement frequency be estimated?
It depends on the actual quantity of target gas adsorbed, flue-gas conditions, bed design and allowable breakthrough, so it cannot be read from the iodine value or CTC figure. Establish loading by representative testing or operating data, then estimate carbon consumption and change-out intervals with the bed volume and operating schedule. Regeneration of flue-gas carbon requires separate assessment of the adsorbed species, carbon loss, strength and any risk of contamination.