Coal-based carbon for gas-phase air duty
Granular Coal-Based Activated Carbon for Air Purification: Gas-Phase Media Selection Guide
Granular coal-based activated carbon is a gas-phase adsorbent for fixed beds, adsorber boxes and air purification systems. Air passes through a packed layer while the pore structure retains odorous and organic molecules, a duty pattern common in solvent vapour recovery, industrial exhaust odour control and spray booth extraction. Selection should rest on the target gas, concentration, temperature, humidity and airflow, not on a single headline figure.
Share target gas, concentration, airflow and bed depth so we can match grade, mesh and CTC range.
- Iodine value
- 500 – 1100 mg/g
- CTC adsorption
- 35 – 95 %
- Hardness
- ≥ 90 %
DESCRIPTION
Explore description details to support your evaluation.
Granular coal-based activated carbon is a gas-phase adsorbent for fixed beds, adsorber boxes and air purification systems handling steady airflow at an acceptable pressure drop. Formed into granules, it lets air pass through a packed layer while its pore structure retains odorous and organic molecules. Typical duties include solvent vapour recovery, industrial exhaust odour control and spray booth extraction, where target compounds suit physical adsorption.
Performance depends on more than one number. Iodine value reflects small-molecule accessible porosity and CTC adsorption indicates behaviour under defined vapour-phase test conditions; neither directly predicts dynamic working capacity for a specific gas stream. Hardness and dust level affect how the bed withstands handling and airflow. Compare batch results against your actual target gas, concentration and contact time.
Selection points to settle before ordering
Define the gas: components, concentration range, temperature and humidity, since high humidity and reactive gases can change behaviour.
Confirm bed depth, velocity, allowable pressure drop and loading method.
Remove oil mist, particulate and water droplets upstream to avoid pore blocking.
Agree grade and acceptance basis: particle size, hardness, ash and moisture on a comparable batch basis.
Consider replacement cycle, spent carbon handling and whether regeneration is being evaluated.
For a relevant proposal, describe the application, components to remove, airflow and concentration data, temperature, humidity, adsorber type, required particle size, quantity and delivery location. If measured data is not yet available, tell us the process and current problem. Batch values and documentation are confirmed by our team before any order.
SPECIFICATIONS
Explore specifications details to support your evaluation.
The table below shows reference ranges for this granular coal-based series. Batch values are confirmed before quotation, and working capacity must be verified under your actual gas conditions.
| Iodine value | 500 – 1100 mg/g |
|---|---|
| CTC adsorption | 35 – 95 % |
| Hardness | ≥ 90 % |
| Methylene blue adsorption | ≥ 90 mg/g |
| BET surface area | 650 – 1000 m²/g |
| Ash content | 8 – 20 % |
| Moisture | ≤ 8 % |
| Bulk density | 0.5 – 0.65 g/cm³ |
| pH value | 7 – 11 |
| Particle size | 4 – 40 目 |
ADVANTAGES
Explore advantages details to support your evaluation.
Gas-phase media decisions rest on verified values and duty fit, not on one headline number.
Coal-based granular form suited to fixed-bed gas duty
Granular coal-based carbon packs into adsorption boxes and filter vessels, where bed depth, contact time and pressure drop can be arranged around the actual airflow.
Fixed-bed geometry
OUR COMMITMENTS
Six Reasons Industrial Buyers Trust Sanniu Carbon
Our inquiry process covers duty review, document scope and order confirmation, without promising fixed prices or delivery dates.
Duty review before any selection advice
We ask what is being treated, at which process stage, and which result you want to improve, then discuss media direction against your target gas, airflow and humidity.
Specification scope stated clearly
We explain the applicable scope of the specifications and documents we cite, and confirm batch values and available files before the transaction is agreed.
Packaging and moisture protection agreed on order
Order confirmation includes packing format, bag type and moisture-control requirements, recorded in the mutually confirmed order information.
Price, quantity and lead time verified manually
Available quantity and delivery time are checked by our staff and stated in a written quotation or order, not inferred from annual capacity or stock assumptions.
Post-delivery questions followed up
Use, documentation and handling questions raised after delivery are received and followed up through the agreed contact channel.
CREDENTIALS
Explore credentials details to support your evaluation.
ISO 9001:2015
Registrati0n No: 06524Q01338R0S
Certificate of Analysis
B-R2409C3836
Certificate of Analysis
Report No. A2260506150101001
Certificate of Analysis
No. 1621112086
Certificate of Analysis
NO.250100320443888
Certificate of Analysis
NO. 1524070087
PACKAGING
Explore packaging details to support your evaluation.
Granular coal-based carbon is packed to protect the bed from moisture and handling damage between plant and filter vessel.
Moisture-barrier inner liner
Bags are supplied with an inner liner that limits moisture pick-up during storage and transport, helping preserve the as-supplied moisture figure on arrival.
Inner liner in each bag
Standard 25 kg bag for manual filling
A 25 kg bag suits smaller vessels, dosing stations and sites where bags are lifted by hand into the adsorption box opening.
25 kg per bag
Bulk bags for larger fixed beds
Larger bags reduce handling labour and loose dust when charging a full filter vessel, and are agreed against the ordered quantity and site lifting equipment.
Bulk format on request
Palletised and unitised loading
Bags can be palletised and unitised for container loading so that the shipment arrives in the agreed configuration and is easier to move into storage.
Palletised for container loading
Packing format recorded on the order
Final bag size, liner and labelling are set out in the confirmed order information, along with any moisture-control requirement for the shipping route.
Confirmed in the written order
PROCESS
Explore process details to support your evaluation.
A typical gas-phase project runs through five defined stages, from defining the duty through first operation, with the goal of confirming fit before full-scale loading.
Define the gas stream and target
Record the components to be removed, inlet concentration range, temperature, relative humidity, airflow and any dust or oil mist. These values set the basis for comparing media.
Set the equipment constraints
Confirm the vessel or adsorber form, allowable pressure drop, bed depth, contact time and the planned change-out or regeneration method before selecting a grain size.
Agree specifications and sample
Fix the grade, mesh range, moisture basis and the key test items on a sample, and keep the report and retained sample linked to the batch for later comparison.
Confirm batch values before order
Series reference ranges are indicative only. Hardness, moisture and adsorption values for the actual batch are confirmed in writing before quotation and shipment.
Commission and monitor
Load the media, check dust and pressure drop at start-up, then track outlet readings against the agreed target so replacement or regeneration timing is based on measurement.
DIMENSIONS
Explore dimensions details to support your evaluation.
Gas-phase duty depends on more than one number. Granular coal-based carbon is selected for target gas, concentration, humidity, airflow and bed design, with hardness and CTC data checked together.
Product form
Granular activated carbon for gas-phase duty
Granular activated carbon sized for fixed beds and continuous gas or flue-gas streams, where pressure drop, hardness and dust behaviour matter alongside adsorption capacity.
Application
Air and gas purification
Odour control, solvent recovery and flue gas treatment, where the carbon has to hold up in the gas phase rather than in a water column.
Material
Coal-based activated carbon
A versatile material family for industrial treatment, with granular, pellet and powder forms selected to suit the process.
FAQ
Explore faq details to support your evaluation.
Buyers comparing granular coal-based carbon for gas-phase duty usually raise the same practical questions before requesting a quote.
How do I choose between iodine value and CTC adsorption for gas-phase use?
CTC adsorption is the more direct reference for gas-phase duty because it uses a vapour probe. Iodine value still describes accessible small-pore adsorption and helps compare overall activity. Both are comparative figures from specified test methods, not a guarantee of dynamic working capacity. Final selection should match the target gas, concentration, temperature, humidity and contact time.
What particle size and pressure drop should I expect in an adsorber?
Particle size and bed depth together set the pressure drop across a packed bed. Finer granules raise resistance and dust carryover; coarser granules lower resistance but may shorten the effective mass-transfer zone. Share your vessel geometry, airflow and allowable pressure drop so the screen fraction and bed design can be reviewed together rather than chosen from one number.
How does moisture in the gas stream affect performance?
Water vapour competes with the target compound for pore space, so high humidity can reduce working capacity and shorten service life. The moisture figure in a specification describes the product as supplied, measured on the batch sample; it is not a reading of the gas stream. Report the operating humidity and temperature range, and consider upstream dehumidification or a suitable grade if water loading is high.
How should the spent carbon be changed or regenerated?
Change-out is judged by breakthrough monitoring at the outlet, not by a fixed calendar interval. Regeneration may be possible for some solvent duties, but recovery of capacity, hardness loss, contamination risk and disposal all need evaluation for the specific adsorbed compound. For mixtures or reactive gases, single-use replacement is often the simpler route. Confirm the approach with your process engineer.
What data should I include with an inquiry?
Describe the gas components and concentration range, flow rate, temperature, humidity, dust or oil pretreatment, equipment type and allowable pressure drop. Add the target outlet limit, required screen fraction, estimated annual quantity and any documentation you need. Provide these before pricing so the grade and agreed specification plan can be confirmed. Quotations and lead times are verified by our team.