Long-life granular activated carbon
Long Service Life Granular Activated Carbon for Cyclic Water Treatment
Coconut shell granular activated carbon is built for water treatment beds loaded, backwashed and returned to service repeatedly. Hardness of 95% or higher helps granules resist attrition and limits fines and pressure-drop growth across cycles. Reference ranges for iodine value, moisture and ash frame capacity and bed stability; batch values are confirmed in writing before quotation. Share your treatment target, flow, contact time and mesh size so selection starts from the real duty.
Hardness of 95% or higher supports repeated service; confirm batch values and operating conditions before ordering.
- Iodine value
- 900 – 1600 mg/g
- Methylene blue adsorption
- 135 – 210 mg/g
- Hardness
- ≥ 95 %
DESCRIPTION
Explore description details to support your evaluation.
Granular activated carbon made from coconut shell suits water treatment systems that are cycled repeatedly, whether in a fixed bed, filter vessel or contact column. The hard, dense granular form supports repeated backwashing, loading and unloading, so the material can serve many cycles rather than being replaced after a short run.
Long service life in cyclic duty comes from several factors acting together. High hardness helps the granules resist attrition during backwash, transport and repeated handling, limiting fines and pressure-drop growth. Low ash and controlled moisture support stable bed behaviour, while a developed pore structure gives room to hold target organics, taste and odour compounds, and residual chlorine.
What to confirm before selection
Service life is set by the actual duty, not the carbon alone. Confirm the treatment target, feed conditions, flow rate and contact time, bed depth, backwash practice and the point when the bed will be changed or regenerated. Specifications shown are reference values for the series; batch values are confirmed before quotation, so compare like-for-like methods, units and sample conditions.
State the target: organics, colour, taste and odour, chlorine or another measured parameter.
Describe the system: fixed bed, filter vessel or column, plus flow, contact time and backwash routine.
Give acceptance criteria and the test method used to judge remaining capacity.
Note particle size needs so the granule range matches retention and pressure-drop limits.
For a relevant inquiry, include the application, flow or batch volume, target outlet condition, existing carbon or bed details, required granule size, quantity and any documentation needed. Our team will check the scenario and advise on a suitable direction; price, availability and delivery are confirmed by quotation or order.
SPECIFICATIONS
Explore specifications details to support your evaluation.
Review iodine value, methylene blue adsorption and hardness together; these reference ranges frame capacity and mechanical durability, while batch values are confirmed before quotation.
| Iodine value | 900 – 1600 mg/g |
|---|---|
| Methylene blue adsorption | 135 – 210 mg/g |
| BET surface area | 950 – 1200 m²/g |
| CTC adsorption | 40 – 99 % |
| Ash content | 1 – 5 % |
| Moisture | 3 – 10 % |
| Hardness | ≥ 95 % |
| Bulk density | 0.45 – 0.55 g/cm³ |
| pH value | 6.5 – 8.5 |
| Particle size | 4 – 40 目 |
| Heavy metals (food grade) | ≤ 10 ppm |
ADVANTAGES
Explore advantages details to support your evaluation.
These advantages focus on what keeps granular carbon working through repeated service cycles in water treatment beds.
Hardness and backwash stability
A hardness reference of at least 95% supports resistance to attrition during backwashing and handling, helping preserve bed integrity across repeated service cycles in fixed-bed water treatment.
Attrition resistance
OUR COMMITMENTS
Six Reasons Industrial Buyers Trust Sanniu Carbon
Our inquiry workflow confirms what a buyer needs before any commercial figure or specification is offered. It keeps selection grounded in the actual water treatment duty.
Use case and target review first
We begin by reviewing the water treatment duty, the target parameter and the required product form, so the discussion of selection direction starts from the actual operating situation rather than a generic grade name.
Specification scope stated clearly
We explain the applicable range of any quoted specification and supporting document, and confirm specific batch values and available files before the transaction is agreed.
Packaging confirmed at order stage
Bag size, liner requirements and moisture-protection measures are checked when the order is confirmed, with the final arrangement recorded in the order information both parties accept.
Price, quantity and lead time by human review
Price, available quantity and delivery time are verified by our team and confirmed in a written quotation or order; annual capacity figures are not treated as stock or delivery promises.
Post-delivery support through agreed channels
We receive and follow up on questions about use or documentation after delivery through the agreed contact channel, without implying fixed response times or performance guarantees.
CREDENTIALS
Explore credentials details to support your evaluation.
ISO 9001:2015
Registrati0n No: 06524Q01338R0S
Certificate of Analysis
B-R2409C3836
Certificate of Analysis
Report No. A2260506150101001
Certificate of Analysis
No. 1621112086
Certificate of Analysis
NO.250100320443888
Certificate of Analysis
NO. 1524070087
PACKAGING
Explore packaging details to support your evaluation.
Granular carbon for cyclic water treatment needs protection from moisture, handling damage and contamination between the plant and the filter bed.
PE-lined bags for moisture protection
Bags with an inner PE liner help limit moisture pickup during storage and transport, which matters because absorbed water reduces the effective carbon weight delivered to the bed.
Standard bag with inner PE liner
Bulk bags for larger fixed beds
Bulk bags reduce handling steps when filling larger vessels or contactors, lowering labor and spillage; the specific size and lifting arrangement are agreed before the order is confirmed.
Bulk bag size confirmed per order
Palletized loading for container shipment
Carbon bags can be palletized for container loading, which supports orderly unloading and reduces bag damage in transit; the exact pallet configuration is matched to the shipment.
Pallet layout agreed per shipment
Desiccant and vacuum options on request
For humid shipping routes, desiccant or vacuum packing can be discussed as a moisture-control measure alongside the standard liner; availability is confirmed at the order stage.
Moisture-control option on request
Packing details fixed at order confirmation
Bag type, net weight, liner, pallet and protective measures are checked against the buyer's storage and filling conditions when the order is confirmed, and recorded in the accepted order documents.
Final packing confirmed in writing
PROCESS
Explore process details to support your evaluation.
A practical sequence for preparing and evaluating a granular carbon bed in cyclic water treatment, where stable operation matters more than a single test result.
Define the treatment target and cycle
Record the target compound, inlet and outlet values, flow or batch volume, contact time and backwash schedule. These define what long service life means for your circuit.
Confirm the grade and mesh size
Match granular carbon grade and particle size to the vessel, flow direction and pressure drop limits. Confirm batch values for hardness, ash and iodine value before ordering.
Condition the bed before service
Rinse and backwash the fresh bed to remove fines and settle the bed. Record initial pressure drop, flow and rinse water quality as the baseline for later comparison.
Track performance across cycles
Sample at set intervals for the target parameter, not only for colour or odour. Log run time, throughput, backwash frequency and carbon loss so changes can be traced to conditions.
Review regeneration and replacement
Assess spent carbon against restored adsorption, hardness loss and fines generation. Decide on regeneration or replacement using your own operating data and agreed acceptance criteria.
DIMENSIONS
Explore dimensions details to support your evaluation.
Granular form supports packed-bed and filter use, where stable hardness and controlled fines help sustain repeated adsorption and backwash cycles over long service.
Product form
Granular activated carbon
Granular media for fixed-bed adsorption and filtration. Compare particle size, pressure drop and handling needs.
Application
Water treatment
Activated carbon selection for water polishing, colour and odour control. Share the water analysis and treatment targets.
FAQ
Explore faq details to support your evaluation.
How should the service life of granular activated carbon be estimated for cyclic water treatment?
Base the estimate on measured capacity, pressure drop and outlet quality rather than a single specification value. Service life depends on inlet concentration, contact time, loading rate and the operating conditions defined for the grade under review. Test the actual batch to support the final estimate.
Which applications does granular activated carbon primarily serve?
Cyclic water treatment where the carbon is retained in a fixed bed, filter column or contactor and then replaced or reactivated after a defined loading period. Typical uses include groundwater and drinking-water treatment, industrial process water polishing, decolorization and odor control. Suitability depends on the target constituents and the overall treatment setup. Different applications may require different pore structure, particle size distribution and mechanical properties, so the final grade should be confirmed through testing.
How should particle size and adsorption capacity be balanced for cyclic operation?
Finer particles generally give faster adsorption kinetics by shortening the path to the internal pore structure, while coarser particles offer lower pressure drop and better retention in fixed beds. For cyclic operation, evaluate a practical balance between pressure drop, contact time and mechanical strength. Assess pressure drop and backwash behavior under actual operating conditions. The selected particle size distribution should correspond to the application geometry and target performance.
How can repeat-use performance be maintained across successive cycles?
Repeat-use performance depends on the operating history and the nature of the adsorbed material. Each cycle should include monitoring of outlet quality, pressure drop and any change in bed condition, and backwash parameters and contact time should be verified against the design. Regeneration can restore capacity, but recovery, mechanical loss and possible introduction of contaminants should be evaluated for the specific application, with feasibility assessed using test data.
Which water parameters should be documented before selecting a grade?
Document inlet and target concentrations, flow rate, pH, temperature and contact time. Note any suspended solids, oil or other components that could affect adsorption or bed operation. Provide the required particle size, allowable pressure drop and any mechanical or chemical constraints. Data should be supplied for the actual batch so the selection can be compared and confirmed.
What information is needed to evaluate a quotation for cyclic water treatment?
Include the treatment objective, flow rate or batch size, inlet and target values, temperature, pH and any permitted pressure drop. Specify the required particle size and the expected operating mode. Pricing and supply should be confirmed through discussion of the requested grade and intended application.