Granular activated carbon for wastewater
Granular Activated Carbon for Wastewater Treatment: Iodine Value, Hardness and Particle Size Selection Guide
Granular activated carbon for wastewater gives plants a packed bed that holds colour, dissolved organics and odour while water passes through at a controlled contact time. This guide explains how iodine value, methylene blue adsorption, hardness and particle size support selection, and which water conditions—flow, pH, suspended solids and backwash—should be confirmed first. Reference ranges help shortlist a grade; batch values and documents are agreed before quotation.
For organic and colour removal: confirm your water conditions, target and particle size before batch values are quoted in writing.
- Iodine value
- 500 – 1100 mg/g
- Methylene blue adsorption
- ≥ 90 mg/g
- Hardness
- ≥ 90 %
- Particle size
- 4 – 40 目
DESCRIPTION
Explore description details to support your evaluation.
Sanniu Carbon supplies coal-based granular activated carbon for wastewater treatment, where the material treats a flowing stream rather than a single batch. Fixed beds, filter columns and contact tanks use a granular product so water passes through the bed at a controlled contact time while the carbon holds colour, dissolved organics and odour-causing compounds. Wastewater is broad, so start by naming what the plant must reduce and what the flow looks like.
Iodine value shows small-molecule adsorption under test conditions, while methylene blue adsorption reflects access to somewhat larger pores; both are comparative indicators, not a prediction of removal for every pollutant in a real effluent. Hardness matters because a filter bed is repeatedly backwashed, and particle size must suit the vessel, flow rate and tolerable pressure drop. Coal-based carbon is a reasonable starting point for water and industrial liquid streams, but the grade still has to match the actual water.
Selection rests on conditions before figures: target compounds or colour, pH, suspended solids and pre-treatment, flow rate or batch volume, contact time, and how spent carbon will be removed or reactivated. Suspended solids and oil can blind the surface and shorten service life, and colour reduction alone does not confirm that COD, toxicity or discharge limits are met. The batch specification is confirmed before quotation.
To make an inquiry useful, describe the wastewater source, target parameter and current level, flow rate or batch volume, pH, suspended solids, the planned contact or filtration setup, and the particle size your equipment accepts. Technical and sales teams then discuss the grade and confirm the batch specification before any offer is made.
SPECIFICATIONS
Explore specifications details to support your evaluation.
Use this table to compare series reference values before a batch is confirmed. Iodine value, methylene blue adsorption and hardness guide selection, but final figures apply to the quoted batch.
| Iodine value | 500 – 1100 mg/g |
|---|---|
| Methylene blue adsorption | ≥ 90 mg/g |
| BET surface area | 650 – 1000 m²/g |
| CTC adsorption | 35 – 95 % |
| Ash content | 8 – 20 % |
| Moisture | ≤ 8 % |
| Hardness | ≥ 90 % |
| Bulk density | 0.5 – 0.65 g/cm³ |
| pH value | 7 – 11 |
| Particle size | 4 – 40 目 |
ADVANTAGES
Explore advantages details to support your evaluation.
Selection points buyers can verify before confirming a granular activated carbon order for wastewater duty.
Granular form suited to fixed-bed and filter duty
Granular carbon supports packed beds and filtration vessels, where contact time, backwashing and pressure drop matter alongside adsorption. Particle size is quoted so the grade can be matched to existing equipment.
Form and bed matching
OUR COMMITMENTS
Six Reasons Industrial Buyers Trust Sanniu Carbon
What we do when handling a wastewater activated carbon inquiry, from first review to post-delivery follow-up.
Inquiry reviewed against the actual application
We ask what is being treated, where the carbon sits in the process, and which target indicator should improve, then discuss a suitable grade and form based on that information.
Scope of specifications and documents explained
We state the scope within which quoted specifications and available reports apply. Batch values and the documents that can be supplied are confirmed before the transaction.
Packing and moisture protection agreed at order
Packing format and moisture-protection requirements are reviewed when the order is confirmed, following the details both sides accept in writing.
Price, available quantity and delivery verified by staff
Quotations, available quantities and delivery dates are checked by our team and confirmed in a written quotation or order. Published capacity figures are not stock or lead-time commitments.
Post-delivery questions followed through agreed channels
After shipment, questions about use of the material or supporting documents are received and followed up through the contact channel agreed with the buyer.
CREDENTIALS
Explore credentials details to support your evaluation.
ISO 9001:2015
Registrati0n No: 06524Q01338R0S
Certificate of Analysis
B-R2409C3836
Certificate of Analysis
Report No. A2260506150101001
Certificate of Analysis
No. 1621112086
Certificate of Analysis
NO.250100320443888
Certificate of Analysis
NO. 1524070087
PACKAGING
Explore packaging details to support your evaluation.
Packing formats for granular activated carbon are selected and confirmed with the order, taking shipment route and moisture exposure into account.
PE-lined bags for moisture-sensitive shipments
Bags with an inner PE liner help limit moisture pickup in transit and storage. The exact bag construction is agreed when the order is placed rather than assumed from a generic list.
Bag size confirmed per order
Bulk bags for larger vessel and filter fills
For bigger fill volumes, bulk bags can reduce handling steps during transfer. The chosen format is matched to the receiving equipment and unloading arrangement at the customer site.
Bulk format agreed at order
Packing chosen for the delivery route
Humidity and transit conditions differ by destination. Where damp routes are a concern, additional moisture protection can be discussed during order confirmation.
Route-dependent, confirmed in writing
Pallet and loading arrangements coordinated
Palletisation and container loading are coordinated with the confirmed packing format so the shipment arrives in a condition the receiving plant can handle safely.
Loading plan agreed before shipment
Order details recorded in writing
Packing specification, quantity and labelling requirements are recorded in the order documents, giving both sides a clear reference for the delivered consignment.
Recorded in order documents
PROCESS
Explore process details to support your evaluation.
A practical sequence for moving from a wastewater problem to a shortlisted granular activated carbon grade.
Describe the water and the target
State the source, flow or batch volume, pH, suspended solids and the parameter you need to reduce, such as colour, COD or odour.
Share current results and constraints
Send existing test data, the current carbon or process step, and limits on contact time, backwashing, pressure drop or spent carbon handling.
Match form and particle size
Confirm whether a fixed bed or slurry dosing suits your plant, then check the particle size range against filtration and loading equipment.
Confirm specifications on a batch basis
Iodine value, hardness, ash and moisture are compared using the same method and unit; quoted values are confirmed for the batch before order.
Agree samples and acceptance checks
Before repeating an order, align on the grade, key test items, sampling method and records so results can be compared over time.
DIMENSIONS
Explore dimensions details to support your evaluation.
Particle size is the first practical choice for wastewater duty: finer mesh raises contact area but complicates filtration and pressure drop, while coarser granules suit packed beds and backwashing.
Product form
Granular activated carbon
Granular media for fixed-bed adsorption and filtration. Compare particle size, pressure drop and handling needs.
Application
Water treatment
Activated carbon selection for water polishing, colour and odour control. Share the water analysis and treatment targets.
Product form
Coal-based granular activated carbon
Granular activated carbon produced from coal, screened to a defined particle size range for fixed beds and continuous water treatment columns.
FAQ
Explore faq details to support your evaluation.
Which data should I provide to select a granular activated carbon for wastewater?
Share the wastewater type, pH, temperature, flow or batch volume, inlet and target values, and whether you use a fixed bed or slurry dosing. Also state your particle size limits, allowable pressure drop, backwash conditions and any metals or impurities you need controlled. With these we can confirm a grade and the agreed specification before quotation.
How do I choose the particle size for a fixed-bed wastewater column?
Balance contact time, pressure drop, backwash and carbon loss. Coarser granules reduce pressure drop and wash-out risk but may need a deeper bed; finer granules can improve mass transfer but raise head loss and filtration demand. The series covers a 4–40 mesh range, so select a narrow band that matches your column, flow and separation equipment rather than one broad cut.
Why compare iodine value, hardness and methylene blue adsorption together?
These tests answer different questions. Iodine value (500–1100 mg/g in the reference range) indicates small-pore accessibility, while methylene blue adsorption (90 mg/g minimum) gives information on larger probe molecules. Hardness (90% minimum) relates to mechanical durability. None predicts real wastewater performance alone; pore structure, ash, contact conditions and competing organics also matter.
How should I plan backwashing and avoid carbon loss?
Backwashing is a site-specific operating decision, not a fixed product promise. Check bed expansion, flow rate, water temperature and the particle size band, and monitor fines in the wash water. Hardness gives comparative mechanical information under a stated method, but does not replace a trial on your column. Start conservatively, observe actual bed behavior and adjust with your equipment supplier.
Which specification details are confirmed before an order?
The reference series range covers iodine value, hardness, methylene blue adsorption, particle size and other listed metrics. Batch values, test methods, particle size distribution and packaging are confirmed before quotation. Speak with your technical contact about which certificates or sample reports apply to the selected grade; a sample report covers the tested sample, not the whole series.
What should a wastewater treatment inquiry include?
Describe the source of the wastewater, process stage, target contaminant or colour, flow rate, contact or dosing method, pH and temperature. Include your existing treatment train, discharge or reuse target, annual quantity and required packaging. Price, available quantity and delivery time are confirmed by our team after these details are reviewed; no quote is generated automatically.