Coal-based granular carbon for water treatment
Coal-Based Granular Activated Carbon for Water Treatment with Long Service Life and High Hardness
This coal-based granular activated carbon suits water treatment beds where replacement frequency matters. Its 8–30 mesh granules balance hydraulic flow with contact time, and hardness of at least 95% helps the bed withstand repeated backwashing. An iodine value of 900–1050 mg/g indicates substantial accessible capacity for small organic molecules, supporting longer working life between changeouts when mesh, contact time and backwash suit your vessel. Share your target contaminant and flow rate to confirm batch values.
High-hardness coal-based granular carbon for fixed beds; request a sample so iodine value, hardness and mesh can be confirmed for your duty.
- Iodine value
- 900 – 1050 mg/g
- Methylene blue adsorption
- ≥ 100 mg/g
- Hardness
- ≥ 95 %
DESCRIPTION
Explore description details to support your evaluation.
This coal-based granular activated carbon is intended for water treatment beds where media replacement frequency matters. Made from selected coal and formed into 8–30 mesh granules, it offers a practical balance between hydraulic flow and contact with the water being treated, and its hardness supports repeated backwashing and handling with limited attrition.
What Supports a Longer Service Life
Bed life depends on working capacity, how quickly that capacity is used, and how much carbon is lost in operation. An iodine value of 900–1050 mg/g indicates substantial accessible capacity for small organic molecules, so more capacity remains before breakthrough. A methylene blue adsorption value of at least 100 mg/g points to accessible transport pores, helping larger organics diffuse into the particle. Hardness of at least 95% supports resistance to backwash shear and handling loss, reducing the carbon loss that would otherwise shorten effective bed life.
Bulk density of 0.5–0.6 g/cm³ helps in calculating bed volume and vessel loading. Moisture is specified at no more than 5%; because it affects the active mass received, dose and price comparisons should use the same basis. Ash content of 8–14% is reported on the batch sample. Water-extract pH of 8–10 does not replace testing in the actual process medium.
Selection Considerations
Confirm the target contaminant and available contact time; capacity per unit mass and working capacity under flow are not the same measure.
Match the particle size cut to vessel, bed depth and backwash capability.
Check hardness and initial fines against your backwash and handling practice.
For a meaningful selection, share the application, flow rate or batch volume, inlet and target values, contact time, preferred mesh range and expected quantity. Batch-specific values can then be confirmed before quotation.
SPECIFICATIONS
Explore specifications details to support your evaluation.
Review these reference ranges with your water conditions in mind; batch values are confirmed before quotation and shipment.
| Iodine value | 900 – 1050 mg/g |
|---|---|
| Methylene blue adsorption | ≥ 100 mg/g |
| BET surface area | 800 – 1000 m²/g |
| CTC adsorption | 45 – 70 % |
| Ash content | 8 – 14 % |
| Moisture | ≤ 5 % |
| Hardness | ≥ 95 % |
| Bulk density | 0.5 – 0.6 g/cm³ |
| pH value | 8 – 10 |
| Particle size | 8 – 30 目 |
ADVANTAGES
Explore advantages details to support your evaluation.
For fixed-bed water treatment, these four points are the ones buyers check first in a coal-based granular grade.
High hardness protects the bed during backwashing
Hardness of 95% or above supports repeated backwash cycles and helps limit attrition losses, an advantage that matters most where the bed is cleaned often and carbon replacement is a planned cost.
Hardness of 95% or above
OUR COMMITMENTS
Six Reasons Industrial Buyers Trust Sanniu Carbon
These are the steps we confirm with each enquiry, not fixed lead times or performance guarantees.
Use case and target reviewed first
On receiving an enquiry we check the application, the treatment target and the product form before discussing a selection direction, so recommendations start from your duty rather than a catalogue name.
Scope of quoted data explained
We state which specification and documents apply to a grade. Batch values and the files we can provide are confirmed before the order, so a sample report is not presented as a full-series certificate.
Packing and moisture protection agreed
At order confirmation we review packing specification and damp protection requirements with you. What ships follows the order information both sides confirm in writing.
Price, quantity and delivery verified by staff
Indicated prices, available quantities and delivery dates are verified manually and confirmed in a written quotation or order. Annual capacity figures are not treated as stock or lead time.
Post-delivery questions followed up
Questions about use or documents after delivery are received and followed up through the agreed contact channels. This describes our working process, not a warranty or sample supply commitment.
CREDENTIALS
Explore credentials details to support your evaluation.
ISO 9001:2015
Registrati0n No: 06524Q01338R0S
Certificate of Analysis
B-R2409C3836
Certificate of Analysis
Report No. A2260506150101001
Certificate of Analysis
No. 1621112086
Certificate of Analysis
NO.250100320443888
Certificate of Analysis
NO. 1524070087
PACKAGING
Explore packaging details to support your evaluation.
PROCESS
Explore process details to support your evaluation.
Define the water treatment duty
State the target contaminant, flow rate, contact time and existing bed or filter setup, so the grade and mesh cut can be matched to the duty rather than chosen by name alone.
Confirm the specification basis
Agree the iodine value, methylene blue value, hardness and mesh range on the same test method and units; batch values are confirmed before quotation.
Select the mesh cut
The 8–30 mesh range suits fixed beds; finer or coarser cuts are discussed per project because particle size affects pressure drop, backwash and carbon loss.
Check bed and loading data
Use bulk density to calculate bed volume and vessel loading, and compare moisture on the same basis so dosing and price rest on the same quantity of dry carbon.
Review documents and place the order
Confirm the packaging, quantity and required batch documents, then send the inquiry for manual verification of price, availability and delivery; no fixed lead time is implied.
DIMENSIONS
Explore dimensions details to support your evaluation.
Granular coal-based carbon holds its bed structure through repeated backwash and service cycles, so operators can plan longer runs between changeouts.
Product form
Granular activated carbon
Granular media for fixed-bed adsorption and filtration. Compare particle size, pressure drop and handling needs.
Application
Water treatment
Activated carbon selection for water polishing, colour and odour control. Share the water analysis and treatment targets.
Material
Coal-based activated carbon
A versatile material family for industrial treatment, with granular, pellet and powder forms selected to suit the process.
FAQ
Explore faq details to support your evaluation.
What information should I include in an inquiry for a water treatment carbon?
Describe the medium to be treated, the flow rate, the target specification, and the required particle size. With those details we can confirm whether this coal-based granular grade fits the duty and agree on the batch specification plan before pricing. Price, available quantity, and lead time are then confirmed in writing by our team.
How do hardness and iodine value relate to service life in a fixed bed?
Hardness is the relevant figure for withstanding backwash cycles and limiting attrition losses, which this grade supports with a minimum of 95%. Iodine value, in a range of 900 to 1050 mg/g, indicates working capacity for smaller molecules. Both figures describe the product under specified test conditions; you still need to compare them against your own contact time, water chemistry, and regeneration or replacement schedule.
Does a higher iodine value always mean a longer service life?
No. Iodine value is a comparative indicator obtained under one test method; it is not a direct measure of how long a bed will last. Service life in water treatment depends on the target organics, competition between them, contact time, pH, backwash practice, and the acceptable breakpoint before replacement. Use the iodine value with the other batch figures rather than as a stand-alone ranking.
What should I prepare for batch comparison and repeat orders?
Agree the key items for acceptance and the method for checking them before shipment. Compare batches on the same basis: measure moisture as supplied, since the figure of 5% or less affects the effective carbon quantity at the same dosing; keep the ash range of 8 to 14% in view for purity-sensitive duties; and retain comparable samples and records. Whether a particular report accompanies each batch is fixed by the order agreement.
Which details should I confirm before placing an order?
Confirm the required mesh cut within the 8 to 30 mesh range, or discuss another cut as a project request. Check the bulk density range of 0.5 to 0.6 g/cm³ for bed volume and vessel loading calculations. State the packaging and moisture-protection requirements, the quantity, and the delivery location so that pricing and timing can be checked and confirmed in writing.