Coal-based carbon for water treatment
Coal-Based Granular Activated Carbon for Water Treatment: Iodine Value 500–1100 mg/g, Hardness ≥90%
Coal-based granular activated carbon for water treatment is designed for fixed beds and filters, where it must retain its shape through backwashing while capturing dissolved organics. This grade suits environmental engineering duties such as taste, odor and color control and organics polishing. Reference values include iodine value 500–1100 mg/g and hardness ≥90%, with batch data confirmed before quotation. Share your water analysis, flow and mesh needs to discuss the grade direction.
Share flow, target organics and bed design; we confirm iodine value, hardness and mesh grade before quotation.
- Iodine value
- 500 – 1100 mg/g
- Methylene blue adsorption
- ≥ 90 mg/g
- Hardness
- ≥ 90 %
- Particle size
- 4 – 40 目
DESCRIPTION
Explore description details to support your evaluation.
Coal-based granular activated carbon is a durable material for water treatment, where fixed beds, filter vessels and contactors need granules that hold their shape through backwashing and repeated service. Made from coal and supplied as granules, it combines a broad pore structure with the mechanical strength packed beds demand. It suits environmental engineering duties such as reducing color, taste and odor, polishing organics after biological treatment, and protecting downstream processes in municipal or industrial water lines.
How it works in a water treatment bed
Water passes through the packed carbon layer, and dissolved organic molecules migrate into the pore network and are held at the internal surface. Contact time, bed depth, flow rate and incoming load all shape the result, so the same carbon can behave differently from one installation to another. Coal-based granules balance smaller pores for low-molecular-weight organics with wider pores that help larger molecules reach adsorption sites. Because the material sits as a fixed bed, granule size and hardness matter as much as adsorption numbers: an agreed particle size range keeps flow distribution predictable, and hardness supports resistance to attrition during backwash and handling.
Selection points worth confirming
Define the target: color, taste and odor, specific organics, or residual concentration after the existing treatment train.
Share the water analysis, pH, temperature and competing compounds so adsorption behavior can be judged realistically.
Confirm the particle size range against the vessel, support layer and backwash conditions rather than choosing by habit.
Review iodine value together with hardness, ash and moisture; one number does not describe performance in every duty.
What to include in an inquiry
A useful inquiry states the application, flow or batch volume, influent and target values, bed or dosing arrangement, preferred particle size range and expected quantity. Batch figures and delivery arrangements are confirmed in writing before quotation.
SPECIFICATIONS
Explore specifications details to support your evaluation.
Values below are series reference ranges unless marked as batch measurements. Confirm the final mesh grade, moisture basis and batch certificate against your application before ordering.
| Iodine value | 500 – 1100 mg/g |
|---|---|
| Methylene blue adsorption | ≥ 90 mg/g |
| BET surface area | 650 – 1000 m²/g |
| CTC adsorption | 35 – 95 % |
| Ash content | 8 – 20 % |
| Moisture | ≤ 8 % |
| Hardness | ≥ 90 % |
| Bulk density | 0.5 – 0.65 g/cm³ |
| pH value | 7 – 11 |
| Particle size | 4 – 40 目 |
ADVANTAGES
Explore advantages details to support your evaluation.
Practical points a buyer can check before committing to a coal-based granular grade for water treatment.
Coal-based granular form for fixed beds
A granular coal-based carbon suited to fixed beds and filters, where contact time, particle size and bed behaviour are considered together with adsorption values.
Form and duty fit
OUR COMMITMENTS
Six Reasons Industrial Buyers Trust Sanniu Carbon
Working with Sanniu Carbon follows a simple inquiry process. We review your application first, then confirm specifications, documents, packing and delivery details in writing before any order.
Scope Clarified Before Quotation
Share your treatment target, flow or batch volume, and current water data. We confirm the applicable product form and the specifications that matter for your process.
Specifications and Documents Stated Up Front
We cite the series specifications and their scope, and confirm batch values and available documents, such as a COA, before the order is placed.
Batch Details Confirmed in Writing
Iodine value, hardness, ash, moisture and mesh grade are agreed against your chosen grade, and recorded in the written quotation or order.
Packaging Checked at Order Confirmation
Bag type, net weight and moisture-protection requirements are reviewed with you, and the agreed packing details are carried into the order.
Follow-Up Through the Agreed Channel
After delivery, questions about handling, storage or the supplied documents are received and followed up through the contact channel we agreed.
CREDENTIALS
Explore credentials details to support your evaluation.
ISO 9001:2015
Registrati0n No: 06524Q01338R0S
Certificate of Analysis
B-R2409C3836
Certificate of Analysis
Report No. A2260506150101001
Certificate of Analysis
No. 1621112086
Certificate of Analysis
NO.250100320443888
Certificate of Analysis
NO. 1524070087
PACKAGING
Explore packaging details to support your evaluation.
Packaging is selected around the granular form, the route and your handling equipment, then confirmed in the order details.
PROCESS
Explore process details to support your evaluation.
A straightforward path from first inquiry to confirmed delivery, focused on matching the carbon grade to your water treatment duty.
Inquiry and application review
Share the treatment target, water conditions, flow or batch volume, and any limits on the existing filters or beds, so the grade can be matched to the duty.
Specification scope confirmed
You receive the applicable series specifications together with the test methods and reference basis, and the batch values to be checked before quotation.
Grade and sizing discussion
Particle size, iodine value, methylene blue adsorption, hardness and other relevant values are discussed against the duty, not compared as an overall ranking.
Order details agreed
Before confirmation, packaging format, moisture protection and the document set required for the shipment are reviewed and recorded in the order information.
Price, quantity and lead time
Commercial terms are checked by a person and confirmed in a written quotation or order; annual capacity is not offered as stock or a delivery promise.
DIMENSIONS
Explore dimensions details to support your evaluation.
Water-treatment duty is set by contact time, influent quality and bed design, not by grade name alone. Check mesh, hardness and iodine value together before specifying a granular coal-based carbon.
Product form
Coal-based granular activated carbon
Granular activated carbon produced from coal, screened to a defined particle size range for fixed beds and continuous water treatment columns.
Application
Water treatment
Activated carbon selection for water polishing, colour and odour control. Share the water analysis and treatment targets.
Material
Coal-based activated carbon
A versatile material family for industrial treatment, with granular, pellet and powder forms selected to suit the process.
FAQ
Explore faq details to support your evaluation.
Five questions buyers ask before specifying coal-based granular activated carbon for water treatment.
What information do you need to recommend a coal-based GAC grade?
Share what you are treating, the process stage, water or wastewater quality, pH, temperature, flow rate or batch volume, current and target values, and whether you plan a fixed bed or powder dosing. Also state available contact time, backwash and filtration conditions, and any limit on target-component loss. With those details we can discuss a grade direction and the parameters to verify. Series reference values such as iodine value 500–1100 mg/g remain indicative until the batch is confirmed before quotation.
How should I compare iodine value, methylene blue adsorption and BET surface area?
Treat each as a different piece of evidence. Iodine value reflects adsorption of a small probe under specified conditions; it is not total pore volume or a removal guarantee for every pollutant. Methylene blue adsorption gives information on a larger probe molecule and pore accessibility. BET surface area describes surface area, not whether a target compound can enter the pores or how fast it moves. Compare values only when method, unit, batch and test conditions match, then confirm suitability with your actual water under the same operating conditions.
What do hardness, ash content and particle size mean for a fixed-bed water filter?
Hardness and abrasion resistance influence how the carbon withstands handling, backwashing and regeneration; read the reported figure with its test method and sample form. Ash content is a total inorganic residue measure, not individual metals or dissolved species. Particle size, given here as a mesh grade agreed per application, affects pressure drop, filtration and contact time. Finer grades may improve mass transfer but can raise pressure drop, fines carryover and carbon loss. Confirm mesh range and bed conditions together.
Can one coal-based GAC grade suit both drinking water and industrial wastewater?
Not necessarily. Drinking water, industrial wastewater and dye decolorization differ in target contaminants, competing substances, pre-treatment and contact conditions. A grade chosen for organics or color in wastewater may not meet potable water's hygiene and material requirements. Coal-based granular carbon is discussed for water treatment, industrial gas and solvent recovery, but the raw material name does not define a grade or prove performance. State the final use and specific requirements so the grade and supporting documents can be reviewed.
How are specifications and test reports confirmed before ordering?
Specifications in this page are series reference ranges unless marked as measured on the batch sample. Batch values are confirmed before quotation. Ask for the parameters, methods, units and limits that matter for your process, and agree which items are checked at batch release. Certificates and reports each have a defined scope: an ISO 9001 certificate for activated carbon sales, or a sample RoHS report, should not be read as approval of every grade for every use. Keep comparable samples and records for incoming verification and repeat orders.
What should I include in an inquiry for pricing and availability?
Include the application and process stage, target contaminants or color, flow rate or batch quantity, pH and temperature, required mesh grade, moisture basis, packaging preference, delivery location and required documents. Note any equipment constraints such as allowable pressure drop or backwash rate. Price, available quantity and lead time are confirmed in a written quotation or order; annual capacity figures do not represent stock or a delivery commitment.